The constant increase in the amount and complexity of information obtained from IT data networkelements, for its correct monitoring and management, is a reality. The same happens to data net-works in electrical systems that provide effective supervision and control of substations and hydro-electric plants. Contributing to this fact is the growing number of installations and new environmentsmonitored by such data networks and the constant evolution of the technologies involved. This sit-uation potentially leads to incomplete and/or contradictory data, issues that must be addressed inorder to maintain a good level of monitoring and, consequently, management of these systems. Inthis paper, a prototype of an expert system is developed to monitor the status of equipment of datanetworks in electrical systems, which deals with inconsistencies without trivialising the inferences.This is accomplished in the context of the remote control of hydroelectric plants and substationsby a Regional Operation Centre (ROC). The expert system is developed with algorithms definedupon a combination of Fuzzy logic and Paraconsistent Annotated Logic with Annotation of TwoValues (PAL2v) in order to analyse uncertain signals and generate the operating conditions (faulty,normal, unstable or inconsistent / indeterminate) of the equipment that are identified as importantfor the remote control of hydroelectric plants and substations. A prototype of this expert systemwas installed on a virtualised server with CLP500 software (from the EFACEC manufacturer) thatwas applied to investigate scenarios consisting of a Regional (Brazilian) Operation Centre, with aGeneric Substation and a Generic Hydroelectric Plant, representing a remote control environment.
翻译:从信息技术数据网络中获得的信息数量和复杂性不断增加,而信息技术数据网络的正确监测和管理,其数量和复杂性不断增加,这是现实。对电系统数据网工作也发生同样的情况,这些系统对分站和水电厂提供有效的监督和控制。造成这种情况的原因是,由这类数据网络和所涉技术的不断演变所监测的装置和新环境越来越多。这种静坐可能会导致数据不完整和/或相互矛盾。为了保持良好的监测水平,从而管理这些系统,必须解决一些问题。在本文件中,开发了一个专家系统的原型,以监测电系统数据网络设备的状况,这种系统处理不一致之处,而不会轻视推断。 这是在对水电厂的远程控制以及由这种数据网络监测产生的新的环境。 专家系统是结合Fuzzy逻辑和对逻辑的附加说明性说明,并用2Value公司(PAL2v)的虚拟说明来进行处理。 开发一个专家系统的原型模型,用以分析电路数据网络设备状况的不确定性和运行情况,代表着一个稳定的、稳定的、稳定的、稳定的、稳定的、稳定的、稳定的、不固定的、稳定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、不固定的、